RP8440升级微码过程

教程发布:风哥 教程分类:ITPUX技术网 更新日期:2022-02-12 浏览学习:183

一、查看partition 状态
MP> cm

Enter HE to get a list of available commands

MP:CM> ps
Display detailed status of the selected MP bus device.

The following MP bus devices were found:
+---+----+-----+-------+-------+-----------+
| | | | | | |
| | | Sys | | IO | Bulk Pwr |
|Cab| MP |Bkpln| Cells |Chassis| Supplies |
| # |M S| |0 1 2 3| 0 1 |0 1 2 3 4 5|
+---+----+-----+-------+-------+-----------|
| 0 |* | * |* | * * |* * * |
+---+----+-----+-------+-------+-----------+
You may display detailed power and hardware status for the following items:
T - Cabinet
S - System Backplane
G - MP (Core I/O)
P - IO Chassis
C - Cell
Select Device: t
HW status for rp8400 cabinet : NO FAILURE DETECTED
Power switch is on
Right Door is closed
Top Door is closed
Left Door is closed
Total Power Available 3000 VA
Total Power Needed 1818 VA
Power Redundancy : redundant
Power Viability : viable

Power Status
---------------+-----+-------+-------+-----------+
| | | | |
| Sys | | IO | Bulk Pwr |
|Bkpln| Cells |Chassis| Supplies |
| |0 1 2 3| 0 1 |0 1 2 3 4 5|
---------------+-----+-------+-------+-----------|
Populated | * |* | * * |* * * |
Enabled | * |* | * |* * * |
Power OK | * |* | * |* * * |
Warning/Fault | | | | |
Attention LED | | | | |

AC Line status:
Line A0 Present
Line B0 Present
Line A1 NOT PRESENT
Line B1 NOT PRESENT
-- Press to continue, or 'Q' to Quit --
Front Fan Speed : normal
Rear Fan speed : normal
I/O Bay Fan Speed : normal
Temperature state : normal
Fan Redundancy : redundant
Overtemp Shutdown Enabled

| BPS | PCI |
| Fans | Fans |
| 0 1 2 3 4 5 | 0 1 2 3 4 5 |
+-----------+-------------+-------------+
Populated | * * * | * * * * * * |
Failing | | |
Failed | | |
| Standby/Main Fans |
| 1 1 1 1 1 1 1 1 1 1 2 |
| 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 |
+-----------+-------------------------------------------+
Populated | * * * * * * * * * * * * * * * * * * * * * |
Failing | |
Failed | |
| Cell Fans |
| 0 1 2 3 4 |
+-----------+-----------+
Cell 0 | |
Populated | * * * * * |
Failing | |
Failed | |
二、测试RP8400的MP LAN 和FTP server 是否联通,并把firmware 文件放在ftp server 自己指定的目录下:/tmp/fw,然后:用命令解开
使用 "gunzip" 解压FW文件。
# gunzip PF_CKEYMAT063.tar.gz
使用 "tar" 解开 firmware 文件。
%

本文标签:
本文标题:RP8440升级微码过程
网站声明:本文由风哥整理发布,转载请保留此段声明,本站所有内容将不对其使用后果做任何承诺,请读者谨慎使用!
【上一篇】
【下一篇】